Descripción del título

ABSTRACT Introduction: Due to the increased toxicity of wastewater and the limited efficiency of conventional systems, the application of alternative processes is required, among which the sono-photo-Fenton system is highlighted. Objective: This work aims at optimizing the variables that directly affect the oxidation power of the sono-photo-Fenton process, such as the pH of the solution and the concentration of the oxidizing and the promoting agents, for the treatment of a petrochemical wastewater, in order to validate the suitability of using designs of experiments based on a reduced number of runs. Materials and methods: For this purpose, a face-centered composite central experiment design was used, whose second-order regression model was validated. The results achieved were compared to those ones reported in the literature using a larger number of experimental runs. Results: Under optimized operating conditions (3 pH units, 525 mg/L H2O2 and 25,70 mg/L Fe2+), COD removals > 70 % were obtained. These results were similar to the optimal conditions previously obtained and informed in the literature by using a full factorial experiment design. Conclusions: Therefore, it is demonstrated the importance of conducting designs of experiments that allow optimizing water treatment systems using a reduced number of runs, which results in the reduction of both economic costs and times of experimentation and analysis of the response variable of interest
RESUMO Introdução. Devido ao aumento da toxicidade das águas residuais e à eficiência limitada dos sistemas convencionais, é necessário aplicar processos alternativos, dentre os quais se destaca o sistema sono-photo-Fenton. Objetivo: Este trabalho busca otimizar as variáveis que afetam diretamente o poder de oxidação do processo sono-foto-Fenton, como o pH da solução e a concentração de oxidante e de agente promotor, para o tratamento de águas residuais de origem petroquímico, a fim de validar a conveniência de usar disenos experimentais com base em um número reduzido de execuções. Materiais e métodos: Para isso, foi utilizado um diseno experimental central composto centralizado na face, cujo modelo de regressão de segunda ordem foi validado. Os resultados alcançados foram comparados aos relatados na literatura com um número maior de execuções experimentais. Resultados: Sob condições operacionais otimizadas (3 unidades de pH, 525 mg/L H2O2 e 25,70 mg/L Fe2+), foram obtidas remoções de DQO > 70 %. Esses resultados foram semelhantes às condições otimas previamente obtidas e informadas na literatura usando um diseño experimento fatorial completo. Conclusões: Portanto, é demonstrada a importância da realização de experimentos que permitam otimizar os sistemas de tratamento de água usando um número reduzido de execuções, o que se traduz na redução de custos econômicos e nos tempos de experimentação e análise da variável resposta em estudo
RESUMEN Introducción: Debido al aumento de la toxicidad de las aguas residuales y a la limitada eficiencia de los sistemas convencionales, se hace necesaria la aplicación de procesos alternativos, entre los que destaca el sistema sono-foto-Fenton. Objetivo: Con este trabajo se busca optimizar las variables que afectan directamente el poder de oxidación del proceso sono-foto-Fenton, tales como el pH de la solución y la concentración de agente oxidante y promotor, para el tratamiento de un agua residual de origen petroquímico, con el fin de validar la conveniencia del uso de diseños de experimentos basados en un número reducido de corridas. Materiales y métodos: Para ello, se utilizó un diseño de experimentos central compuesto centrado en las caras, cuyo modelo de regresión de segundo orden obtenido fue validado. Los resultados alcanzados fueron comparados con los reportados en la literatura usando un mayor número de corridas experimentales. Resultados: Bajo condiciones de operación optimizadas (3 unidades de pH, 525 mg/L de H2O2 y 25,70 mg/L de Fe1+) se obtuvieron remociones de DQO > 70 %. Estos resultados fueron similares a las condiciones óptimas obtenidas e informadas previamente en la literatura utilizando un diseño de experimentos factorial completo. Conclusiones: Se demuestra, por tanto, la importancia de llevar a cabo diseños de experimentos que permitan optimizar sistemas de tratamiento de aguas usando un reducido número de corridas, lo cual se traduce en la reducción tanto de costos económicos como de tiempos de experimentación y análisis de la variable respuesta objeto de estudio
Analítica
analitica Rebiun32438183 https://catalogo.rebiun.org/rebiun/record/Rebiun32438183 220905s2020 xx o 000 0 spa d https://dialnet.unirioja.es/servlet/oaiart?codigo=8039073 (Revista) ISSN 1909-0455 S9M oai:dialnet.unirioja.es:ART0001472971 https://dialnet.unirioja.es/oai/OAIHandler 12 DGCNT S9M S9M dc Optimización del proceso sono-foto-Fenton para el tratamiento de aguas residuales usando un diseño central compuesto electronic resource] 2020 application/pdf Open access content. Open access content star ABSTRACT Introduction: Due to the increased toxicity of wastewater and the limited efficiency of conventional systems, the application of alternative processes is required, among which the sono-photo-Fenton system is highlighted. Objective: This work aims at optimizing the variables that directly affect the oxidation power of the sono-photo-Fenton process, such as the pH of the solution and the concentration of the oxidizing and the promoting agents, for the treatment of a petrochemical wastewater, in order to validate the suitability of using designs of experiments based on a reduced number of runs. Materials and methods: For this purpose, a face-centered composite central experiment design was used, whose second-order regression model was validated. The results achieved were compared to those ones reported in the literature using a larger number of experimental runs. Results: Under optimized operating conditions (3 pH units, 525 mg/L H2O2 and 25,70 mg/L Fe2+), COD removals > 70 % were obtained. These results were similar to the optimal conditions previously obtained and informed in the literature by using a full factorial experiment design. Conclusions: Therefore, it is demonstrated the importance of conducting designs of experiments that allow optimizing water treatment systems using a reduced number of runs, which results in the reduction of both economic costs and times of experimentation and analysis of the response variable of interest RESUMO Introdução. Devido ao aumento da toxicidade das águas residuais e à eficiência limitada dos sistemas convencionais, é necessário aplicar processos alternativos, dentre os quais se destaca o sistema sono-photo-Fenton. Objetivo: Este trabalho busca otimizar as variáveis que afetam diretamente o poder de oxidação do processo sono-foto-Fenton, como o pH da solução e a concentração de oxidante e de agente promotor, para o tratamento de águas residuais de origem petroquímico, a fim de validar a conveniência de usar disenos experimentais com base em um número reduzido de execuções. Materiais e métodos: Para isso, foi utilizado um diseno experimental central composto centralizado na face, cujo modelo de regressão de segunda ordem foi validado. Os resultados alcançados foram comparados aos relatados na literatura com um número maior de execuções experimentais. Resultados: Sob condições operacionais otimizadas (3 unidades de pH, 525 mg/L H2O2 e 25,70 mg/L Fe2+), foram obtidas remoções de DQO > 70 %. Esses resultados foram semelhantes às condições otimas previamente obtidas e informadas na literatura usando um diseño experimento fatorial completo. Conclusões: Portanto, é demonstrada a importância da realização de experimentos que permitam otimizar os sistemas de tratamento de água usando um número reduzido de execuções, o que se traduz na redução de custos econômicos e nos tempos de experimentação e análise da variável resposta em estudo RESUMEN Introducción: Debido al aumento de la toxicidad de las aguas residuales y a la limitada eficiencia de los sistemas convencionales, se hace necesaria la aplicación de procesos alternativos, entre los que destaca el sistema sono-foto-Fenton. Objetivo: Con este trabajo se busca optimizar las variables que afectan directamente el poder de oxidación del proceso sono-foto-Fenton, tales como el pH de la solución y la concentración de agente oxidante y promotor, para el tratamiento de un agua residual de origen petroquímico, con el fin de validar la conveniencia del uso de diseños de experimentos basados en un número reducido de corridas. Materiales y métodos: Para ello, se utilizó un diseño de experimentos central compuesto centrado en las caras, cuyo modelo de regresión de segundo orden obtenido fue validado. Los resultados alcanzados fueron comparados con los reportados en la literatura usando un mayor número de corridas experimentales. Resultados: Bajo condiciones de operación optimizadas (3 unidades de pH, 525 mg/L de H2O2 y 25,70 mg/L de Fe1+) se obtuvieron remociones de DQO > 70 %. Estos resultados fueron similares a las condiciones óptimas obtenidas e informadas previamente en la literatura utilizando un diseño de experimentos factorial completo. Conclusiones: Se demuestra, por tanto, la importancia de llevar a cabo diseños de experimentos que permitan optimizar sistemas de tratamiento de aguas usando un reducido número de corridas, lo cual se traduce en la reducción tanto de costos económicos como de tiempos de experimentación y análisis de la variable respuesta objeto de estudio LICENCIA DE USO: Los documentos a texto completo incluidos en Dialnet son de acceso libre y propiedad de sus autores y/o editores. Por tanto, cualquier acto de reproducción, distribución, comunicación pública y/o transformación total o parcial requiere el consentimiento expreso y escrito de aquéllos. Cualquier enlace al texto completo de estos documentos deberá hacerse a través de la URL oficial de éstos en Dialnet. Más información: https://dialnet.unirioja.es/info/derechosOAI | INTELLECTUAL PROPERTY RIGHTS STATEMENT: Full text documents hosted by Dialnet are protected by copyright and/or related rights. This digital object is accessible without charge, but its use is subject to the licensing conditions set by its authors or editors. Unless expressly stated otherwise in the licensing conditions, you are free to linking, browsing, printing and making a copy for your own personal purposes. All other acts of reproduction and communication to the public are subject to the licensing conditions expressed by editors and authors and require consent from them. Any link to this document should be made using its official URL in Dialnet. More info: https://dialnet.unirioja.es/info/derechosOAI Spanish diseño de experimentos tratamiento del agua proceso avanzado de oxidación contaminante persistente contaminación design of experiments water treatment advanced oxidation process persistent pollutant pollution diseno de experimentos tratamento de água processo avançado de oxidação contaminante persistente contaminação text (article) Castrillón-Marín, Mateo. cre Rubio Clemente, Ainhoa. cre Producción + Limpia, ISSN 1909-0455, Vol. 15, Nº. 2, 2020, pags. 24-45 Producción + Limpia, ISSN 1909-0455, Vol. 15, Nº. 2, 2020, pags. 24-45 Producción + Limpia, ISSN 1909-0455, Vol. 15, Nº. 2, 2020, pags. 24-45