Descripción del título

Huila is a Colombian state with a high production of Oreochromis fish, its contribution to national production is of 53%, that is distributed in 338 hectares of ponds on land and floating cages. The environmental and climatic characteristics of the region allow having dissolved oxygen production in the ponds between 4ppm and 12ppm during the day, but at night the situation is unfavorable, since the amount of dissolved oxygen can decrease up to 1ppm while carbon dioxide increases. Therefore, it is necessary to have adequate oxygenation equipment and systems to prevent delayed in fish growth and to decrease death rates. This article presents the design and implementation of an automatic dissolved oxygen control system by manipulation of a water recirculation flow that operates in parallel with an industrial oxygen generator. The implemented system tracks and records the temperature and oxygen variables present in the geomembrane tank to evaluate the process evolution for different periods of the fish development cycle. The data was acquired using an Atlas Scientific dissolved oxygen sensor kit and a DS18B20 temperature probe they send the data directly to a Raspberry Pi that transmits by wireless the information collected from the process to the SISCEFA web server and a mobile application through which users can observe the data traceability. The dissolved oxygen concentration was maintained within the threshold established and the fish rate death decrease
Huila es catalogado como uno de los departamentos con mayor producción de tilapia en Colombia, aporta el 53% de la producción total del país con 338 hectáreas de estanques en tierra y jaulas flotantes. Las características ambientales y climatológicas de la región permiten alcanzar una producción de oxígeno que oscila entre 4ppm y 12ppm durante el día, sin embargo, en las noches la situación no es tan favorable, pues la cantidad de oxígeno disuelto puede disminuir hasta 1ppm mientras la de dióxido de carbono aumenta. Por tanto, se requieren equipos y sistemas de oxigenación para evitar retrasos en el crecimiento de los peces y disminuir las tasas de mortalidad. En este artículo se presenta un sistema automático que controla la concentración de oxígeno disuelto manipulando un caudal de recirculación de agua que opera en paralelo con un generador de oxígeno industrial. El sistema monitorea y registra las variables de temperatura y oxígeno presentes en una geomenbrana para generar históricos que permitan evaluar el proceso. La adquisición de los datos se realizó por medio de un sensor de oxígeno de la empresa Atlas Scientific y una sonda de temperatura DS18B20, los cuales envían los datos directamente a una Raspberry Pi que transmite de forma inalámbrica la información recolectada del proceso a un servidor web SISCEFA y a una aplicación móvil a través de las cuales los usuarios pueden observar la trazabilidad de los datos. El sistema mantuvo el oxígeno disuelto dentro de los límites establecidos y la mortalidad de peces disminuyó
Analítica
analitica Rebiun33875814 https://catalogo.rebiun.org/rebiun/record/Rebiun33875814 230421s2020 xx o 000 0 eng d https://dialnet.unirioja.es/servlet/oaiart?codigo=7368090 (Revista) ISSN 0122-1701 S9M oai:dialnet.unirioja.es:ART0001379000 https://dialnet.unirioja.es/oai/OAIHandler 16 DGCNT S9M S9M dc Automatic Dissolved Oxygen Control to Oreochromis Fish's Crop in Geomembrane Tank electronic resource] 2020 application/pdf Open access content. Open access content star Huila is a Colombian state with a high production of Oreochromis fish, its contribution to national production is of 53%, that is distributed in 338 hectares of ponds on land and floating cages. The environmental and climatic characteristics of the region allow having dissolved oxygen production in the ponds between 4ppm and 12ppm during the day, but at night the situation is unfavorable, since the amount of dissolved oxygen can decrease up to 1ppm while carbon dioxide increases. Therefore, it is necessary to have adequate oxygenation equipment and systems to prevent delayed in fish growth and to decrease death rates. This article presents the design and implementation of an automatic dissolved oxygen control system by manipulation of a water recirculation flow that operates in parallel with an industrial oxygen generator. The implemented system tracks and records the temperature and oxygen variables present in the geomembrane tank to evaluate the process evolution for different periods of the fish development cycle. The data was acquired using an Atlas Scientific dissolved oxygen sensor kit and a DS18B20 temperature probe they send the data directly to a Raspberry Pi that transmits by wireless the information collected from the process to the SISCEFA web server and a mobile application through which users can observe the data traceability. The dissolved oxygen concentration was maintained within the threshold established and the fish rate death decrease Huila es catalogado como uno de los departamentos con mayor producción de tilapia en Colombia, aporta el 53% de la producción total del país con 338 hectáreas de estanques en tierra y jaulas flotantes. Las características ambientales y climatológicas de la región permiten alcanzar una producción de oxígeno que oscila entre 4ppm y 12ppm durante el día, sin embargo, en las noches la situación no es tan favorable, pues la cantidad de oxígeno disuelto puede disminuir hasta 1ppm mientras la de dióxido de carbono aumenta. Por tanto, se requieren equipos y sistemas de oxigenación para evitar retrasos en el crecimiento de los peces y disminuir las tasas de mortalidad. En este artículo se presenta un sistema automático que controla la concentración de oxígeno disuelto manipulando un caudal de recirculación de agua que opera en paralelo con un generador de oxígeno industrial. El sistema monitorea y registra las variables de temperatura y oxígeno presentes en una geomenbrana para generar históricos que permitan evaluar el proceso. La adquisición de los datos se realizó por medio de un sensor de oxígeno de la empresa Atlas Scientific y una sonda de temperatura DS18B20, los cuales envían los datos directamente a una Raspberry Pi que transmite de forma inalámbrica la información recolectada del proceso a un servidor web SISCEFA y a una aplicación móvil a través de las cuales los usuarios pueden observar la trazabilidad de los datos. El sistema mantuvo el oxígeno disuelto dentro de los límites establecidos y la mortalidad de peces disminuyó LICENCIA DE USO: Los documentos a texto completo incluidos en Dialnet son de acceso libre y propiedad de sus autores y/o editores. Por tanto, cualquier acto de reproducción, distribución, comunicación pública y/o transformación total o parcial requiere el consentimiento expreso y escrito de aquéllos. Cualquier enlace al texto completo de estos documentos deberá hacerse a través de la URL oficial de éstos en Dialnet. Más información: https://dialnet.unirioja.es/info/derechosOAI | INTELLECTUAL PROPERTY RIGHTS STATEMENT: Full text documents hosted by Dialnet are protected by copyright and/or related rights. This digital object is accessible without charge, but its use is subject to the licensing conditions set by its authors or editors. Unless expressly stated otherwise in the licensing conditions, you are free to linking, browsing, printing and making a copy for your own personal purposes. All other acts of reproduction and communication to the public are subject to the licensing conditions expressed by editors and authors and require consent from them. Any link to this document should be made using its official URL in Dialnet. More info: https://dialnet.unirioja.es/info/derechosOAI English Automatic Control Dissolved Oxygen Oreochromis fish Automatización Control Oxígeno Disuelto Pez Oreochromis text (article) Perdomo Gómez, Gustavo Adolfo. cre Corredor Galvis, Karina. cre Duarte Rivera, Santiago. cre Botina Trujillo, Kelyn Rosely. cre Mendez Pastrana, Diego Andres. cre Scientia et Technica, ISSN 0122-1701, Vol. 25, Nº. 1, 2020, pags. 97-103 Scientia et Technica, ISSN 0122-1701, Vol. 25, Nº. 1, 2020, pags. 97-103 Scientia et Technica, ISSN 0122-1701, Vol. 25, Nº. 1, 2020, pags. 97-103