Descripción del título

The quality of the water supplied for human consumption must be known to the entire population, since there are rules that must be met so that the water reaches users in optimal conditions. The design of an instrument is presented in this article to measure the concentration of residual chlorine in drinking water, based on spectroscopic processes, by reacting orthotolidine the content of residual chlorine or its derivatives in drinking water, since there is an absorption spectrum in the range of 350 to 700 nm associated with thisphenomenon. It has been used as a radiation source a laser diode, a photoresistor and a registration system that uses the digital analog converter microcontroller for decoding and subsequent presentation of reading in numeric displays LCD type (liquid crystal display). The proposed instrument was calibrated with reagent amounts of 1 ml to 10 ml of water and residual chlorine concentrations ranging from 0.8 to 1.5 ppm, obtained directly. This design is an alternative user-friendly and easy handling with the application of standards
El agua suministrada para consumo humano tiene que ser sometida a controles de calidad, los cuales deben ser de conocimiento de toda la población, pues existen normas de obligatorio cumplimiento para que este líquido llegue en óptimas condiciones a sus destinatarios. Se presenta en este artículo el diseño de un instrumento para medir la concentración de cloro residual en el agua potable; este objeto está fundamentado en procesos espectroscópicos, mediante la reacción de la ortotolidina con el contenido de cloro residual o alguno de sus derivados, presentes en el agua potable, dado que hay un espectro de absorción en el rango de 350 a 700 nm asociado a este fenómeno. Se ha utilizado como fuente de radiación un diodo láser, una fotorresistencia y un sistema de registro que hace uso del convertidor análogo digital por microcontrolador para la decodificación y posterior presentación de la lectura en visualizadores numéricos de tipo LCD (liquid crystal display). El instrumento propuesto fue calibrado con cantidades de reactivo de 1 ml para 10 ml de agua y concentraciones de cloro residual comprendidas entre 0,8 y 1,5 ppm, obtenidas directamente. Este diseño es una alternativa de fácil uso y cómoda manipulación con la aplicación de normas vigentes
Analítica
analitica Rebiun34966764 https://catalogo.rebiun.org/rebiun/record/Rebiun34966764 240121s2015 xx o 000 0 spa d https://dialnet.unirioja.es/servlet/oaiart?codigo=8793411 (Revista) ISSN 2665-2544 S9M oai:dialnet.unirioja.es:ART0001577362 https://dialnet.unirioja.es/oai/OAIHandler 16 DGCNT S9M S9M dc Aplicación de la espectrometría en la determinación de la concentración de cloro residual en el agua potable utilizada para consumo humano electronic resource] 2015 application/pdf Open access content. Open access content star The quality of the water supplied for human consumption must be known to the entire population, since there are rules that must be met so that the water reaches users in optimal conditions. The design of an instrument is presented in this article to measure the concentration of residual chlorine in drinking water, based on spectroscopic processes, by reacting orthotolidine the content of residual chlorine or its derivatives in drinking water, since there is an absorption spectrum in the range of 350 to 700 nm associated with thisphenomenon. It has been used as a radiation source a laser diode, a photoresistor and a registration system that uses the digital analog converter microcontroller for decoding and subsequent presentation of reading in numeric displays LCD type (liquid crystal display). The proposed instrument was calibrated with reagent amounts of 1 ml to 10 ml of water and residual chlorine concentrations ranging from 0.8 to 1.5 ppm, obtained directly. This design is an alternative user-friendly and easy handling with the application of standards El agua suministrada para consumo humano tiene que ser sometida a controles de calidad, los cuales deben ser de conocimiento de toda la población, pues existen normas de obligatorio cumplimiento para que este líquido llegue en óptimas condiciones a sus destinatarios. Se presenta en este artículo el diseño de un instrumento para medir la concentración de cloro residual en el agua potable; este objeto está fundamentado en procesos espectroscópicos, mediante la reacción de la ortotolidina con el contenido de cloro residual o alguno de sus derivados, presentes en el agua potable, dado que hay un espectro de absorción en el rango de 350 a 700 nm asociado a este fenómeno. Se ha utilizado como fuente de radiación un diodo láser, una fotorresistencia y un sistema de registro que hace uso del convertidor análogo digital por microcontrolador para la decodificación y posterior presentación de la lectura en visualizadores numéricos de tipo LCD (liquid crystal display). El instrumento propuesto fue calibrado con cantidades de reactivo de 1 ml para 10 ml de agua y concentraciones de cloro residual comprendidas entre 0,8 y 1,5 ppm, obtenidas directamente. Este diseño es una alternativa de fácil uso y cómoda manipulación con la aplicación de normas vigentes LICENCIA DE USO: Los documentos a texto completo incluidos en Dialnet son de acceso libre y propiedad de sus autores y/o editores. Por tanto, cualquier acto de reproducción, distribución, comunicación pública y/o transformación total o parcial requiere el consentimiento expreso y escrito de aquéllos. Cualquier enlace al texto completo de estos documentos deberá hacerse a través de la URL oficial de éstos en Dialnet. Más información: https://dialnet.unirioja.es/info/derechosOAI | INTELLECTUAL PROPERTY RIGHTS STATEMENT: Full text documents hosted by Dialnet are protected by copyright and/or related rights. This digital object is accessible without charge, but its use is subject to the licensing conditions set by its authors or editors. Unless expressly stated otherwise in the licensing conditions, you are free to linking, browsing, printing and making a copy for your own personal purposes. All other acts of reproduction and communication to the public are subject to the licensing conditions expressed by editors and authors and require consent from them. Any link to this document should be made using its official URL in Dialnet. More info: https://dialnet.unirioja.es/info/derechosOAI Spanish absorption spectroscopy electromagnetic waves ortotolidina espectroscopia de absorción ondas electromagnéticas ortotolidina text (article) Norato Tobo, Julio Enrique. cre Romero Munévar, Mario Alberto. cre Herrera Paloma, Myriam. cre Letras ConCiencia TecnoLógica, ISSN 2665-2544, Nº. 13, 2015 (Ejemplar dedicado a: Diciembre), pags. 6-14 Letras ConCiencia TecnoLógica, ISSN 2665-2544, Nº. 13, 2015 (Ejemplar dedicado a: Diciembre), pags. 6-14 Letras ConCiencia TecnoLógica, ISSN 2665-2544, Nº. 13, 2015 (Ejemplar dedicado a: Diciembre), pags. 6-14